¿Aún no es miembro de TradeKey.com? Regístrese para conectarse con 9 millones de importadores y exportadores a nivel mundial.
registro |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
IG541 Fire suppression system
Next

IG541 Fire suppression system

( Negotiable )

|

1 Set Minimum Order

País:

China

N º de Modelo:

IG541

Precio FOB:

( Negotiable ) Obtener el precio más reciente

Lugar de origen:

-

Precio de pedido mínimo:

-

Cantidad de pedido mínimo:

1 Set

Detalle de embalaje:

carton

El tiempo de entrega:

15-25days

Capacidad de suministro:

1000 Set per Month

Tipo de pago:

T/T, L/C, Western Union

Grupo de productos :

Contactar ahora
Miembro Básico

Persona de contacto Ms. Michelle

wushan, cixi, Zhejiang

Contactar ahora

Descripción del producto

Specifications

 
IG541 Fire suppression system
environment completely without damage;
completely harmless to human body
 

IG541 Fire suppression system

 

1. System introduction

 

mixed gas IG541 is made up of 52% 40% 40% nitrogen, argon, carbon dioxide mixture of proportion by the steric (physical) way,in a short period of time after discharge to the protection zone can make protection 

zone of the oxygen concentration is reduced to support combustion under 12.5%, and burning fire smothering action implementation, on the other hand, according to the long-term medical experiments prove that the

human body in 12.5% oxygen concentration and the concentration of 2% to 5% carbon dioxide environment 

breath, brain of oxygen and at normal atmospheric environment (21% oxygen concentration and co2 

concentration 0.03%) gained by the oxygen content is the same. This is because in hypoxia environment, if carbon dioxide concentrations increased to 2% 5% can make people breathing deepen and accelerate, 

in unit time make the person obtains enough oxygen to brain cells. Mixed gas IG541, 8% of the carbon 

dioxide gas is artificially make the protection zone of rising carbon dioxide levels to meet the anoxic environment breathing for 2% 5%, and won't cause harm to human body.

1.3 system structure 

1.3.1 unit independent system 
image
2.PART  OF THE SYSTEM
image

2.System main technical parameters 

20 °C storage pressure: 15 MPa 

fire extinguishing agent storage bottles of specifications/filling quantity: 80 l / 80 l / 16.8 Kg, 16.8 Kg 

maximum working pressure (50 °C) : 17.2 MPa 1 start mode: magnetic start, mechanical emergency start 

 

electromagnetic drive air pressure: 6.0 + / - 1.0 MPa (20 °C) 

electromagnetic drive starting power: DC24V / 1.5 A 1.2.7 agent application time: 60 s or less

protection zone temperature: 0 °C to 50 °C 1.2.9 store between bottle temperature: 0 °C to 50 °C

3.System operation principle 
 

1. mixed gas IG541 automatic fire extinguishing system with automatic, manual, mechanical emergency operation three kinds of start ways. 

2.condition automatically, if a protection zone occurs with smoke (or temperature), the protection zone, smoke fire detector (or temperature) movement and the fire alarm controller into a single fire alarm, fire alarm 

controller that is into the single state, drive electric alarm signal of a single fire alarm at the same time, this time will not start the fire extinguishing system of control signals. As the spread of fire protection zone,

the temperature rising smoke (or increase), the other primary circuit heat or smoke fire detector, the controller into a single fire signal, the controller immediately confirm that there is a fire, at the same time signal 

composite fire alarm and linkage (closed air conditioning, ventilation device and fire damper, fire doors, 

fire shutter, etc.). After 30 seconds of time delay, tThe controller output signal to start the fire extinguishing system, cast into the fire extinguishing agent through the pipeline to implement fire protection zone. Controller 

receives the feedback signal of pressure signal after the show bright deflated lights, avoid straying. In manual mode, alarm controller only when the fire broke out a fire alarm signals and does not produce linkage. 

3. requires automatic or manual mode, the personnel on duty after confirmation of fire, press the alarm controller on the front panel or the scene of the "emergency start"  to start the fire extinguishing 

system immediately. Before discharge control signal output, press the alarm controller on the front panel or the scene of the "emergency stop" , the system will not discharge signal output.

País: China
N º de Modelo: IG541
Precio FOB: ( Negotiable ) Obtener el precio más reciente
Lugar de origen: -
Precio de pedido mínimo: -
Cantidad de pedido mínimo: 1 Set
Detalle de embalaje: carton
El tiempo de entrega: 15-25days
Capacidad de suministro: 1000 Set per Month
Tipo de pago: T/T, L/C, Western Union
Grupo de productos : IG541 Fire Suppression System

Send a direct inquiry to this supplier

A:

Ms. Michelle < Wofu & Security Fire Equipement Co., LTD >

quiero saber: